Bofa

H-1173 Budapest, Kaszáló street 115.
Tel: +36-20-260-6018
Fax: +36-1-258-6522
About Us Products WEBSHOP Contact Discount
Laser
Mechanical Engineering
Electronic
Printing
Dental & Pure Beauty

Laser Fume Extraction

ADVANTAGE ORACLE



The complete, Global Solution for high performance laser fume extraction.
- Auto sensing voltage (90-257v) for global use
- Closed Loop Automatic Flow Control
- 2 Stage F8 pre filter with 12m2 of surface area
- Small Footprint and Low Noise levels
- Reverse Flow
- "Easy-Seal" Filter Location

Introducing Bofa's most technically advanced Laser Fume Extractor. The AD Oracle packs a powerful range of unique features into one compact unit.

The revolutionary Auto-Voltage Sensing Pump automatically self adjusts to run on any voltage worldwide, whilst the Reverse Flow filter technology enhances filter performance and ensures longer filter life.

Closed Loop, Automatic Flow Control allows the user to preset correct flow rates, for lower noise levels and further protection of both the combined filter and the 2 stage F8 pre filter, which has a massive 12m2 of surface area.

Back...


Part Numbers

Model - Stainless Steel (SS) or
Powder Coated (PC) options

24V Start/Stop

Filter change/
System failure signal

VOC Monitoring

Hose Kit *

AD ORACLE-SS

L1954A

A2001

A2002

A2003

A1020008
75-50mm

AD ORACLE-PC

L1944A

A2001

A2002

A2003

A1020008
75-50mm

* Other Hose Kits are available. All of the above units are fitted with our standard filter combinations.
For specific applications please call us for details.

Back...


Replacement Filters and Accessories *

Model

Pre Filter

Combined HEPA/Gas Filter

AD ORACLE

A1030156

A1030155

* Other Filters are available. Please call us for details.

Back...


Technical Data

Model

AD ORACLE

EC

US

Dimensions (h × w × d)

980 × 430 × 430 mm

38.5 × 17 × 17"

Cabinet Construction

Brushed stainless steel/
Powder coated mild steel

Brushed stainless steel/
Powder coated mild steel

Blower

1.1kw 380m3/hr

1.1kw 223cfm

Electronics

100-240v 1ph 50/60Hz
Full load current: 12.5 amps

100-240v 1ph 50/60Hz
Full load current: 12.5 amps

Back...


Filter Specification

Pre Filter

Surface Media Area

12m2 approx

Filter Media

Glass Fibre

Filter Media Construction

Maxi Pleat

Housing

Zintec mild steel

Filter Efficiency

F8 (95% @ 0.8 microns)

Combined Filter

HEPA Filter

Media Glass Fibre

HEPA Media Construction

Maxi Pleat Construction with Webbing Spacers

Filter Efficiency

H13 (99.997% @ 0.3 microns)

Treated Activated Carbon

15kgs

Filter Housing

Zintec Mild Steel

Back...


AD ORACLE Pre Filter

Back...


AD ORACLE Combined Filter

Back...


Components Diagram

1. Unit/Filter Condition Display - Automatic Closed Loop Flow Control
2. On/Off Switch
3. Power Cable
4. Signal/ Interface Cable to Laser
5. Filter Housing Cam Latch
6. Door Hinge
7. Hose Inlet Connection
8. Exhaust Outlet
9. Motor Cooling Inlet

Back...


Airflow Through Filters

Back...