Bofa

H-1173 Budapest, Kaszáló street 115.
Tel: +36-20-260-6018
Fax: +36-1-258-6522
About Us Products WEBSHOP Contact Discount
Laser
Mechanical Engineering
Electronic
Printing
Dental & Pure Beauty

Laser Fume Extraction

ADVANTAGE 350



Cost Effective Extraction solutions for Light Duty, Laser Marking, Coding and Engraving.
- Blower with high airflow
- Low cost replacement filters
- Optional VOC gas sensors
- Optional interface with stop/start, filter blocked and extractor failure signals

BOFA's Advantage 250 and 350 fume extraction and filtration systems have been designed to provide cost effective solutions for light duty applications. These compact and extremely quiet systems are ideal for use in schools, sign making workshops, small scale industrial environments and light laser coding applications.

Back...


Part Numbers

Model - Stainless Steel (SS) or
Powder Coated (PC) options

24V Start/Stop

Filter change/
System failure signal

VOC Monitoring

Hose Kit *

AD350-SS

230V

L0552A

A2001

A2002

A2003

A1020011
100mm

115V

L0551A

AD350-PC

230V

L0542A

A2001

A2002

A2003

A1020011
100mm

115V

L0541A

* Other Hose Kits are available. All of the above units are fitted with our standard filter combinations.
For specific applications please call us for details.

Back...


Replacement Filters snd Accessories *

Model

Pre Filter

Combined HEPA/Gas Filter

AD350

A1030056

A1030055

* Other Filters are available. Please call us for details.

Back...


Technical Data

Model

AD350

EC

US

Dimensions (h × w × d)

600 × 380 × 380 mm

23,6 × 14,9 × 14,9"

Cabinet Construction

Brushed stainless steel /
Powder coated mild steel

Brushed stainless steel /
Powder coated mild steel

Blower

204 watts (256) 400m3/hr

255 watts (256) 235cfm

Electronics

230v 1ph 50/60Hz
Full load current: 1.9 amps

115v 60/50Hz
Full load current: 2.5 amps

Back...


Filter Specifications

Pre Filter

Filter Media

Glass Fibre

Surface Media

Area 6m2 approx

Filter Media Construction

100mm Maxi Fold construction
with Webbing Spacers

Filter Housing

Cardboard

Filter Efficiency

F8 (95% @ 0.8 microns)

Combined Filter

Filter Media

Glass Fibre

HEPA Media Construction

Maxi Fold Construction with Webbing Spacers

Gasket

Neoprene with Adhesive Backing

Filter Efficiency

H13 (99.997% @ 0.3 microns)

Activated Carbon

8.5 Kgs approx

Filter Housing

Zintec Mild Steel

Back...


AD 350 Pre Filter

AD 350 Combined Filter

Back...


Components Diagram

1. Unit/Filter Condition Display
2. On/Off Switch
3. Filter Compartment Latch
4. Motor Cooling In & Out
5. Hose Inlet Connection 50 or 75mm
6. Signal/Interface Cable or Laser
7. Power Cable
8. Exhaust Outlet

Back...


Airflow Through Filters

Back...