Bofa

H-1173 Budapest, Kaszáló street 115.
Tel: +36-20-260-6018
Fax: +36-1-258-6522
About Us Products WEBSHOP Contact Discount
Laser
Mechanical Engineering
Electronic
Printing
Dental & Pure Beauty

Laser Fume Extraction

ADVANTAGE 2000
"Clam Shell"


For the Laser Marking, Cutting and Engraving Industries.
- High airflow blower
- 3 stage filtration
- Filter condition display
- Built in silencing
- Long life filters with low replacement costs
- Unique easy open "Clam Shell" and "Gull Wing" doors for filter access
- Automatic closed loop flow control for consistant airflow throughout filter life

BOFA’s NEW AD2000 and AD4000 laser fume extraction units combine large filter capacity with high airflows. This combination makes them ideal for large laser engravers, laser cutters as well as multiple laser coding installations.

Easily accessible filters are accommodated by the uniquely styled "clam shell" and "gull winged" doors, which allow for maximum space and ease when changing filters.

Unit interfaces such as stop/start and system failure are available as options.

Back...


Part Numbers

Model

24V Start/Stop

Filter change/
System failure signal

VOC Monitoring

AD2000

L2543A0000

A2001

A2002

A2003

* Other Hose Kits are available. All of the above units are fitted with our standard filter combinations.
For specific applications please call us for details.

Back...


Replacement Filters snd Accessories *

Model

Pre Filter

HEPA Filter

Gas Filter

AD2000

A130186

A1030182

A1030185

* Other Filters are available. Please call us for details.

Back...


Technical Data

Model

AD2000

EC

US

Dimensions (h × w × d)

1450 × 1460 × 820mm

57,08 × 57,48 × 32,28"

Cabinet Construction

Powder coated mild steel

Powder coated mild steel

Blower

Centrifugal / Radial Fan

Centrifugal / Radial Fan

Electronics

400V / 3Ph / 50Hz
4kw / 7.8A

480V / 3Ph / 60Hz
4.8kw / 7.8A

Weight

Approx 300kg

Approx 660Lbs

Noise level

64dB

64dB

Back...


Filter Specification


Pre Filter

Filter Media

Glass Fibre

Filter Media Construction

Pleated panel

Filter Efficiency

F6 (75% @ 0.8 microns)


Gas Filter

Gasket

Neoprene with Adhesive Backing

Activated Carbon

35 Kgs approx

Filter Housing

Zintec Mild Steel


HEPA Filter

HEPA Filter Media

Glass Fibre

HEPA Media Construction

Maxi Fold Construction with Webbing Spacers

Filter Efficiency

H13 (99.997% @ 0.3 microns)

Filter Housing

Zintec Mild Steel

Surface area

38.5m2 approx

Back...


AD 2000 Pre filter

AD 2000 Gas filter

AD 2000 HEPA Filter

Back...


Components Diagram

1. Unit/Filter Condition Display - Automatic Closed Loop Flow Control
2. On/Off Switch
3. Filter Housing Cam Latch
4. Extracted Ait Outlet
5. Hose Inlet Connection 125mm × 2
6. Signal/ Interface Cable to Laser
7. Power Cable
8. Motor Cooling In/Out
9. Lid handle
10. Lid latch

Back...


Airflow Through Filters

Back...